16.6. Heating Properties
16.6.1. Current frequency
16.6.2. Volume Charge
16.6.3. Data Definition
See Fig. 9.1.3. for selecting the Induction heating simulation mode. For Electrical and Magnetic material properties refer section 10.8. Electromagnetic data.
DEFORM FEM engine can now handle induction heating models with dual frequency input data for current frequency in both 2D & 3D.

Induction Heating Object properties window for Single frequency settings

Induction Heating Object properties window for Dual frequency settings
Current frequency [2D, 3D]
Specifies the frequency of current for heating object. It can be a constant value or a function of time.
Volume Charge [2D, 3D]
Volume charge can be in three modes:
- Current Density : It is a measure of the density of electrical current. It is defined as a vector whose magnitude is the electric current per cross-sectional area. Current density unit is Amp/mm2 or Amp/inch2 in 2d axi-symmetry model and 3d model. In 2d plane model case, coil cross section will be edge line, and thickness is unit length, so current density unit will be Amp/mm or Amp/inch.
- Input power : The electrical power taken by a power tool from the energy source.
- Voltage drop : It is the reduction in voltage in an electrical circuit between the source and load.
Data Definition [2D, 3D]
Data definition can be a constant or function of time for a volume charge of Input power, Current Density and Voltage Drop type.
Related Topics: