🇬🇧 EN 🇸🇰 SK
DEFORM V14.0.2 Manual

TNOW

(Simulation control)
Last updated on : 08-08-2013

TNOW GlobalTime LocalTime FuncTmMd 2ndStgTime


OPERAND DESCRIPTION DEFAULT
GlobalTime Current global time 0.0
LocalTime Local time 0.0
FuncTmMd Function time method = 0 Use global time for function = 1 Use local time for function  
2ndStgTime The second-stage time 0.0

DEFINITION

TNOW specifies the current simulation process time. (2ndStgTime is used for timing the second stage of a simulation, if the simulation contains two stages. For example, in hydraulic forming, a dwell may follow the forming. Thus the clock of the second global time starts when the dwell starts. This is a sort of like multiple operations but in one simulation.)

REMARKS

For initial runs GlobalTime = 0. For continuing and remeshing runs, GlobalTime indicates the current process time at the specified step number. If GlobalTime, LocalTime or 2ndStgTime is less than -1E20, the input value will be ignored. This is to facilitate updating one of them without changing the other (useful in multiple operations). Applicable simulation types: Isothermal Deformation, Heat Transfer, Non-Isothermal Deformation

Keywords: TMAX, TLOC, CURSIM