ECRFLX
| (Object data –3D) |
|---|
| Last updated on : 13-08-2013 |
ECRFLX Object1, Ndata, Default
- Num(1), node1(1) node2(1) node3(1) node4(1) Flux(1)
-
:
Num(Ndata), node1(Ndata) node2(Ndata) node3(Ndata) node4(Ndata) Flux(Ndata)
| OPERAND | DESCRIPTION | DEFAULT |
|---|---|---|
| Object | Object number | None |
| Ndata | Number of face data sets | None |
| Default | Default value for face electric current flux | 0.0 |
| Num(i) | ith data pair | None |
| node1(i) | 1st node defining face i | |
| node2(i) | 2nd node defining face i | |
| node3(i) | 3rd node defining face i | |
| node4(i) | 4th node defining face i | |
| Flux(i) | Distributed electric current flux of ith data pair |
DEFINITION
ECRFLX specifies the distributed electric current flux to be applied to individual faces.
REMARKS
Distributed electric current flux is defined as electric current per unit time per unit area. The electric current flux is assumed to be constant over the face it is defined over. In order to activate electric current flux, the edges must be specified using the keyword ECCRHT with a boundary condition code of 3. Electric current flux may be specified as a function of time with keyword ECRHFN. Applicable object types: : Rigid, Elastic, Plastic, Elastoplastic and Porous.
RELATED TOPICS
Object Edge data: Electric Heating, Boundary Constraints: Heating Keywords: ECCRHT (2D), ECCRHT (3D), ECRHFN (2D), ECRHFN (3D)