🇬🇧 EN 🇸🇰 SK
DEFORM V14.0.2 Manual

CURRNT

(Object data - 2D)
Last updated on : 29-07-2013

CURRNT Object, Ndata, DefCURRNT

Element(1), CURRNT_x(1), CURRNT_y(1)

:

Element(Ndata), CURRNT_x(Ndata), CURRNT_y(Ndata)


OPERAND DESCRIPTION DEFAULT
Object Object number None
Ndata Number of element/CURRNT pairs None
DefCURRNT Default elemental CURRNT of all elements not listed in the element/CURRNT pairs 0
Element(i) Element number of ith data pair None
CURRNT_x(i) Electric current flux x component 0
CURRNT_y(i) Electric current flux y component 0

DEFINITION

CURRNT is the calculated electric current flux at each element center.

REMARKS

Electric current flux at element center is a vector. This state variable is used in simulations of resistance heating.

Simulation Mode: Heat transfer, Heating, Induction Keywords: ZEFI, ZMFI