WININD
| (Simulation control data) | |
|---|---|
| Update History: V11.1 - WININD has been introduced only for 3D. | Last updated on : 21-05-2016 |
WININD Win#, Window_shape, Velocity type
{Vx, Vy, Vz} or {velocity function data}
{Window coordinates}
| OPERAND | DESCRIPTION | DEFAULT |
|---|---|---|
| Win# | Window number | None |
| Window_shape | Window shape =1 rectangular =2 cylindrical | None |
| Velocity type | Velocity type =1 constant =2 function of time =-n follow Object#n | None |
| velocity function data | Function data that defines the velocity | None |
| Vx | Unit direction vector for gravity in X dir. | None |
| Vy | Unit direction vector for gravity in Y dir. | None |
| Vz | Unit direction vector for gravity in Z dir. | None |
| Window coordinates | Coordinates of points that define the window | None |
DEFINITION
WININD specifies the window for induction heating calculation.
REMARKS
WININD is only for 3D. If WININD is defined, the induction heating calculation is carried out only inside the window area. This will save computation time.
RELATED TOPICS
Similar keywords: WINATM(2D), WINATM(3D) , WINPRS(2D), WINPRS(3D), WINRSE, WINTMP (2D). WINTMP(3D)