🇬🇧 EN 🇸🇰 SK
DEFORM V14.0.2 Manual

VFACTR

(Simulation control - 3D)  
Update History: v11 - VFACTR (3D view factor calculation) keyword has been introduced. Last updated on : 12-08-2013

VFACTR SwitchOn

or

VFACTR Switch, NumObject (for NumObject > 0)

Object(1),.. , Object(NumObject)


OPERAND DESCRIPTION DEFAULT
SwitchOn On/off flag = 0 Off = 1 On 0
NumObject Total number of objects None
Object(i) List of objects None

DEFINITION

VFACTR determines whether inter-object heat transfer by radiation is computed in the simulation. It also specifies the list of objects for view factor calculation in 3D when the object is listed.

REMARKS

Only when NumObject > 0, the object list can be provided. This keyword was available only in 2D v10.2 release. It becomes available for 3D as well in v11 release.

Simulation Controls: Process conditions - Heat transfer Related keywords: ENVTMP, CNVCOF