🇬🇧 EN 🇸🇰 SK
DEFORM V14.0.2 Manual

GEOERR

(Simulation control)  
Update History: v11 – Contact tolerances for thermal and wear calculations have been introduced. Last updated on : 07-08-2013

GEOERR Res, Ren,Thermal, Wear


OPERAND DESCRIPTION DEFAULT
Res Relative error limit in tangential direction 1.0 E-06
Ren Relative error limit in normal direction 1.0 E-04
CtlTol Contact tolerance for thermal calculation (new in v11) 0.0
Wear Contact tolerance tool wear calculation (new in v11) 0.0

DEFINITION

GEOERR specifies the values of error limits in geometry handling.

REMARKS

The DEFORM system calculates the overall geometry size, geosiz, and the absolute error limits in tangential and normal directions are determined by aes = geosiz * Res aen = geosiz * Ren Geometric lengths smaller that aes and aen are neglected. If CtlTol is specified, in addition to deformation contact, the interface heat transfer calculations are as follows: If CtlTol > 0, calculation between surface elements with normal distance less than CtlTol. If CtlTol < 0, relative tolerance will be decided based upon testing.

Simulation Controls: Advanced Controls- Error Tolerances, Geometry