DTSUB
| (Simulation control - 2D) |
|---|
| Last updated on : 30-07-2013 |
DTSUB Substepping
| OPERAND | DESCRIPTION | DEFAULT |
|---|---|---|
| Sub-stepping | Indicator controlling sub-stepping | 0.0 (for 2-D) |
DEFINITION
After either DSMAX or DTMAX is prescribed, the deformation simulation may be broken into smaller substeps, depending on the assigned value of DTSUB.
REMARKS
For a default DTSUB = 0.0, the system will enable contact sub-stepping. For DTSUB = 1.0, no sub-stepping will be done. Applicable simulation types: Isothermal Deformation, Non-Isothermal Deformation
RELATED TOPICS
Step Definition Keywords: DTMAX, DSMAX