UNTE2H
| (Simulation control) |
|---|
| Last updated on : 08-08-2013 |
UNTE2H Cfactor
| OPERAND | DESCRIPTION | DEFAULT |
|---|---|---|
| Cfactor | Factor for converting mechanical energy to heat energy | 1.0 SI unit 0.107 (Btu/Klb/in) |
DEFINITION
UNTE2H specifies the factor for converting mechanical work to heat.
REMARKS
Mechanical energy is converted to heat energy using: Eheat = Emechanical * Cfactor Applicable simulation types: Non-Isothermal Deformation
RELATED TOPICS
Keywords: FRAE2H